65
16.2. Operation and Setting at the Time of Emergency Broadcast
• When the emergency broadcast is initiated, the program playback in operation is stopped, allowing the
emergency broadcast to take precedence.
• The EV-700 returns to the Lock mode after the emergency broadcast is stopped.
• Emergency broadcast is disabled while the Maintenance indicator is lighting. (Except when making emergency
playback through the front panel operation)
[Emergency broadcast setting contents list]
Emergency playback R.E.M. playback
Setting range
Factory-preset
setting
Setting range
Factory-preset
setting
Repeat count 0 to 127 times, innite Innite 0 to 127 times, innite Innite
Repeat time
5 to 120 minutes (in
5-minute units), innite
Innite
5 to 120 minutes (in
5-minute units), innite
Innite
Repeat interval
0 to 50 seconds (in
10-second units), 1 to
99 minutes (in 1-minute
units)
0 second
0 to 50 seconds (in
10-second units), 1 to
99 minutes (in 1-minute
units)
0 second
Busy output during interval ON/OFF ON ON/OFF ON
Priority level 1 1 1 1
Emergency playback busy
output destination
Contact control output
terminals 1 − 8
Contact control
output terminals
1, 2
Contact control output
terminals 1 − 8
Contact control
output terminals
1, 2
R.E.M. busy output
destination (See p. 87.)
− −
Contact control output
terminals 1 − 8
None
Output destination
Line output 1,
Line output 2
Line output 1,
Line output 2
Line output 1,
Line output 2
Line output 1,
Line output 2
Program sound volume 0 − 10 10 0 − 10 10
AGC ON/OFF ON ON/OFF ON