Do you have a question about the Tomey UD-800 and is the answer not in the manual?
Measurement Type | Optical biometry |
---|---|
Measurement Items | Axial length, corneal curvature, anterior chamber depth, lens thickness |
IOL Calculation Formulas | SRK/T, Hoffer Q, Holladay 1, Holladay 2, Haigis |
Display | LCD |
Printer | Built-in thermal printer |
Power Supply | AC 100-240 V, 50/60 Hz |
Corneal Curvature Measurement Range | 5 to 10 mm |
Data Output | USB |
Corneal Curvature Measurement Accuracy | ±0.05 mm |
Describes the structure and organization of the manual.
Explains the meaning of symbols used throughout the document.
Details safety precautions and important information before using the instrument.
Lists items to check for completeness and damage after unpacking the instrument.
Provides definitions for technical terms and abbreviations used in the manual.
Gives a general description of the instrument's functions and capabilities.
Identifies and describes the components on the front panel of the main unit.
Identifies and describes the components on the back panel of the main unit.
Identifies and describes components located on the sides of the main unit.
Details the various elements and displays on the instrument's screen.
Explains the meaning of various symbols used for marking on the instrument.
Covers initial setup steps including connecting cables and powering on the instrument.
Explains how to perform B mode imaging, including settings and image acquisition.
Details the biometry function, including measurement conditions and procedures.
Covers the process of calculating IOL power using various formulas and parameters.
Explains how to perform statistical processing on examination data.
Describes the pachymetry function for measuring corneal thickness.
Details the A-scan diagnosis function, including measurement and analysis.
Covers functions for exporting, printing, and saving measurement data.
Allows configuration of various system settings, including measurement and connectivity.
Presents various IOL power calculation formulas used by the instrument.
Explains the methods for calculating axial length with the biometry function.
Describes the input/output characteristics of amplifiers for A-scan diagnosis.
Details MI and TIS parameters related to ultrasonic wave output.
Outlines the terms and conditions of the limited warranty for the product.
States the designed operational lifespan of the instrument.
Provides guidance on when and how to perform instrument inspections.
Details regular maintenance tasks to ensure proper instrument function.
Instructions for replacing consumable items like fuses and printer paper.
Guidelines for storing the instrument safely and appropriately.
Information on the proper disposal of the instrument and its components.
Addresses common issues such as the instrument not starting or the screen being dark.
Troubleshooting steps for issues related to axial length measurement and probe application.
Troubleshooting steps for pachymetry issues like probe errors and out-of-range measurements.
Lists consumable items such as ultrasound gel, fuses, and printer paper.
Lists optional accessories and probes available for the instrument.
Details technical specifications for the B mode image diagnosis 10MHz B-Probe.
Provides information on the ultrasonic wave output quantities and standards.
Describes the sources of machine noise generated during instrument operation.
Specifies the recommended environmental conditions for operating and storing the instrument.
Details the classification of the instrument regarding protection against electric shock and IP codes.
Provides information regarding electromagnetic compatibility and precautions for use.