HiPer Ga/Gb Configuration
HiPer Ga/Gb Operator’s Manual
3-20
Figure 3-16. Receiver Configuration – MINTER Tab
Recording Interval parameter This parameter specifies the logging
rate of the log file when the MINTER FN key (pressed for 1–5
seconds) activates data logging. This setting is used for both logging a
single log file and logging receiver data in AFRM mode. Values are
1–86400 seconds. The default value is one second.
Elevation Mask for Log File parameter This parameter specifies the
minimum elevation angle for the satellites whose data is put in the
receiver files logged when pressing the FN key. The default value is
five degrees.
File Name Prefix parameter This parameter specifies the prefix
added to the names of receiver files created when pressing the FN
key. The prefix can be up to 20 characters long. The default value for
the Name Prefix is “log.
Log file names have the following structure:
<prefix><month><day><sequential alphabet letter>
The file name depends on both the file creation time (month and day)
and additional letter suffixes to avoid confusion between files created
on the same day.
Always Append to the File parameter If you want new receiver
data to be appended to an existing log file, enter the desired file name
in this parameter. The setting can be up to 20 characters long.