Fault
ID
FaultTitle
Contro-
ller(s)
Affected
FaultCondition
/Circuit
Description
Additional
Notes
ServiceActions
P110D
TractionCoil1
FWD-Validation
Failure-PWM
Converge
T1PWMconvergence
ischecking2fault
conditions.The
rstcheckisto
conrmthatthe
PWMdutycycle
acrossthecoilis
decreasingwhen
thedesiredcurrent
tothecoilis0.
Thisensuresthe
voltageacrossthe
coilisapproaching
0whenrequired.
Thesecondcheck
toverifythatthe
PWMdutycycle
acrossthecoilis
notgreaterthan
themaxallowed
limit.
Tractionis
disabledand
machinewill
cometoa
suddenstop.
1.UsetheInfoCentertoverifythetraction
coiloperation.
2.Ifnoamperagereadingisdisplayed:
A.Checkthetractioncoilwiringand
connector(P74,pin17).
B.Testthetractioncoilwiring.
3.Testthetractioncoil.
4.SwaptheT1:Primarycontrollerwitha
known-goodunit(contactanAuthorized
ToroDistributorforassistance).
P110E
TractionCoil1
FWD-Feedback
Measurement
Validation
Failure
T1Theexpected
circuitfeedback
(calculated)does
notmatchthe
measuredcircuit
feedback.
Tractionis
disabledand
machinewill
cometoa
suddenstop.
1.UsetheInfoCentertoverifythetraction
coiloperation.
2.Ifnoamperagereadingisdisplayed:
A.Checkthetractioncoilwiringand
connector(P74,pin17).
B.Testthetractioncoilwiring.
3.Testthetractioncoil.
4.SwaptheT1:Primarycontrollerwitha
known-goodunit(contactanAuthorized
ToroDistributorforassistance).
P1114
TractionCoil
1REV-
Overcurrent
T1
Overcurrent
detectedon
tractioncoil1REV
(NeutralREV).
Indicatesshortto
ground.
1.UsetheInfoCentertoverifythetraction
coiloperation.
2.Ifnoamperagereadingisdisplayed:
A.Checkthetractioncoilwiringand
connector(P74,pin32).
B.Testthetractioncoilwiring.
3.Testthetractioncoil.
4.SwaptheT1:Primarycontrollerwitha
known-goodunit(contactanAuthorized
ToroDistributorforassistance).
Troubleshooting:Page3–22
Groundsmaster
®
4500-D/4700-D
19245SLRevA