Fault
ID
FaultTitle
Contro-
ller(s)
Affected
FaultCondition
/Circuit
Description
Additional
Notes
ServiceActions
P111CTractionCoil1
REV-Validation
Failure-Current
Converge
T1Acurrentmonitor
whichvalidates
theintended
tractioncoilcurrent
isindicating
anunexpected
variancebetween
thedesiredlevel
ofcurrenttothe
tractioncoiland
theactuallevel
ofcurrenttothe
tractioncoil.
Itisexpectedthat
theactuallevel
ofcoilcurrent
willtrackthe
desiredlevelof
currentsetby
thedrive-by-wire
module.
Tractionis
disabledand
machinewill
cometoa
suddenstop.
1.UsetheInfoCentertoverifythetraction
coiloperation.
2.Ifnoamperagereadingisdisplayed:
A.Checkthetractioncoilwiringand
connector(P74,pin32).
B.Testthetractioncoilwiring.
3.Testthetractioncoil.
4.SwaptheT1:Primarycontrollerwitha
known-goodunit(contactanAuthorized
ToroDistributorforassistance).
P111D
TractionCoil1
REV-Validation
Failure-PWM
Converge
T1PWMconvergence
ischecking2fault
conditions.The
rstcheckisto
conrmthatthe
PWMdutycycle
acrossthecoilis
decreasingwhen
thedesiredcurrent
tothecoilis0.
Thisensuresthe
voltageacrossthe
coilisapproaching
0whenrequired.
Thesecondcheck
istoverifythatthe
PWMdutycycle
acrossthecoilis
notgreaterthan
themaxallowed
limit.
Tractionis
disabledand
machinewill
cometoa
suddenstop.
1.UsetheInfoCentertoverifythetraction
coiloperation.
2.Ifnoamperagereadingisdisplayed:
A.Checkthetractioncoilwiringand
connector(P74,pin32).
B.Testthetractioncoilwiring.
3.Testthetractioncoil.
4.SwaptheT1:Primarycontrollerwitha
known-goodunit(contactanAuthorized
ToroDistributorforassistance).
P111E
TractionCoil1
REV-Feedback
Measurement
Validation
Failure
T1Theexpected
circuitfeedback
(calculated)does
notmatchthe
measuredcircuit
feedback.
Tractionis
disabledand
machinewill
cometoa
suddenstop.
1.UsetheInfoCentertoverifythetraction
coiloperation.
2.Ifnoamperagereadingisdisplayed:
A.Checkthetractioncoilwiringand
connector(P74,pin32).
B.Testthetractioncoilwiring.
3.Testthetractioncoil.
4.SwaptheT1:Primarycontrollerwitha
known-goodunit(contactanAuthorized
ToroDistributorforassistance).
P1164
Swashplate1-
SignalShorted
toGnd
T1
Shorttoground
detectedonswash
platesensorsignal.
PTOis
disabled
traction
speedis
reducedby
50%.
Checkforshortedwire(P74,pin28).
Groundsmaster
®
4500-D/4700-D
Page3–23Troubleshooting:
19245SLRevA