TestProcedure(continued)
CAUTION
Beforeopeninghydraulicsystem,operateallhydrauliccontrolsto
relievesystempressureandavoidinjuryfrompressurizedhydraulic
uid;refertoReleasingPressurefromtheHydraulicSystem(page
6–8).
g230036
Figure85
1.Piston(traction)pump
3.Hydraulictube
2.Oillter/lteradapter
4.T estport
g230037
Figure86
1.Piston(traction)pump3.O-ring5.Spring
2.Plug
4.Shimkit6.Chargereliefpoppet
4.Cleantestportonhydraulictubebetweenpiston(traction)pumpandoillter
(Figure85).Connecta6,900kPa(1,000psi)pressuregaugetotestport.
Reelmaster
®
5410/5510/5610Series
Page6–63
HydraulicSystem:TestingtheHydraulicSystem
15216SLRevC