EasyManua.ls Logo

Toro Reelmaster 5510-D - Page 255

Toro Reelmaster 5510-D
662 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TestProcedure(continued)
g217946
Figure137
1.Liftcontrolmanifold2.SVRVsolenoid3.T estport(G4)
4.Cleanthetestport(G4)onthebottomofliftcontrolmanifold,andthen
connecta35,000kPa(5,000psi)pressuregaugetothetestport(Figure
137).
5.Afterinstallingthepressuregaugetothemanifoldtestport,starttheengine
andrunitatlow-idlespeed.Checkforhydraulic-uidleaksfromthetest
connectionsandcorrectbeforecontinuingthetest.
6.Presstheenginespeedswitchtofullspeed(3,005to3,055rpm)position.
UsetheInfoCentertocheckthattheenginespeediscorrect.
IMPORTANT
Donotallowthepressuretoexceed17,500kPa(2,500psi).
IMPORTANT
Whenperformingthistest,holdthejoystickleverintheRAISE
position,onlylongenoughtogetasystempressurereading.
HoldingtheleverinRAISEforanextendedperiodmaydamage
systemcomponents.
7.EnsurethatthereelengageswitchisOFF,andthenpullthejoysticklever
rearwardtopressurizetheliftcircuit.WhileholdingleverintheRAISE
(rearward)position,monitorthepressuregaugecarefully.
8.Whenthecuttingunitsreachthefullyraisedpositionandtheliftreliefvalve
lifts,thesystempressureshouldbeapproximately13,800kPa(2,000psi).
9.ReturnthejoysticklevertotheNEUTRALposition,andshutofftheengine.
10.Ifthemeasuredpressureisincorrect,removethesolenoidreliefvalve
(SVRV)fromtheliftcontrolmanifoldandcleanorreplacethevalve;referto
ServicingtheLiftControlManifold(page6–198).
11.Also,iftheliftcircuitpressureislow,checkfortherestrictioningearpump
inletline.TheInternalliftcylinderleakagewouldalsocauselowliftcircuit
pressure;refertoTestingtheLiftCircuit–LiftCylinderInternalLeakage
Reelmaster
®
5410/5510/5610Series
Page6–137
HydraulicSystem:TestingtheHydraulicSystem
15216SLRevC

Table of Contents

Other manuals for Toro Reelmaster 5510-D

Related product manuals