RemovingtheLiftControlManifold(continued)
CAUTION
Beforeopeningthehydraulicsystem,operateallthehydraulic
controlstoreleasesystempressureandavoidinjuryfromthe
pressurizedhydraulicuid;refertoReleasingPressurefromthe
HydraulicSystem(page6–8).
5.Disconnectthehydraulichosesandtubesfromthettingsinthemanifold.
Allowthelinestodrainintoasuitablecontainer.Removeanddiscardthe
O-ringsfromthettings.
6.Installcleancapsorplugsonthehydraulichosesandttingstoprevent
systemcontamination.
7.Forassemblypurposes,labelallthesolenoidcoilwireharnessleads.
Disconnectthewireharnessleadsfromthesolenoidcoilsonthemanifold.
8.Removethe2ange-headscrewsthatsecurethemanifoldtothemachine
frame.
9.Removetheliftcontrolmanifoldfromthemachine.
g217168
Figure168
1.Straighttting(2each)3.Orice(0.046)(2each)5.Straighttting(6each)
2.O-ring(8each)4.Orice(0.028)(3each)6.Orice(0.055)(3each)
IMPORTANT
Aowcontroloriceisplacedbelowseveralhydraulicttingson
theliftcontrolmanifold(Figure168).Theliftcontrolmanifolduses3
differentoricesizes.Ifthettingsareremovedfromthemanifold
andanoriceisinthemanifoldport,ensurethatyouremovethe
oriceandlabelitspositionforassemblypurposes.
10.Ifnecessary,removethehydraulicttingsfromthemanifold,anddiscard
theO-rings.
11.Locate,retrieve,andlabeltheoricefromthemanifoldport(ifequipped).