11
ET (4 Fields to set: Maximum and Default X whole and decimal values)
Default ET (evapotranspiration) is the minimum ET gure (in millimeters) that is used as the default ET regardless of the weather condi-
tions or if data is missing from the ET gauge or weather station. ET can vary depending on the time of the season and weather. Generally,
daily ET can be from 0mm to 13mm.
Maximum ET is the maximum ET value that can be accumulated between watering days. This value is the maximum value that a program
will ever replace in a single day. Typically choose a value that is your maximum daily ET multiplied by the number of days between watering.
Language (1 Field to set)
Specify the language the Controller should use. English is the default language.
2 3 41
ENTER
- OR -
ENTER
- OR -
2 31
ENTER
- OR -
ENTER
- OR -
ET
Maximum: 05.00 mm
Default: 02.00 mm
** SAVED! **
Maximum: 05.00 mm
Default: 02.00 mm

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toro Sentinel and is the answer not in the manual?

Toro Sentinel Specifications

General IconGeneral
TypeModular
MountingWall
EnclosureNEMA 3R
CommunicationEthernet
Water ManagementMaster Valve
CompatibilityToro
StationsUp to 48
Power SupplyIncluded