67
SENSOR1 0 0 0 0 0 0 0 0 , 0 0 0 0 0 1 1 1
| | | | | | | | | Thermal head open sensor
| | | | | | | | 1: Head closed
| | | | | | | | (* Do not print when head is open)
| | | | | | | |
| | | | | | | | Front cover open sensor
| | | | | | | 1: Cover closed
| | | | | | | (* Do not print when cover is open)
| | | | | | |
| | | | | | | Cutter home position sensor
| | | | | | 0: Outside home position
| | | | | | 1: Home position
| | | | | |
| | | | | | Blank (0 fixed)
| | | | |
| | | | | Ribbon take-up motor sensor
| | | | 0: Outside slit
| | | | 1: In slit
| | | |
| | | | Ribbon back tension motor sensor
| | | 0: Outside slit
| | | 1: In slit
| | |
| | | Blank (0 fixed)
| |
| | Peel sensor
| 0: No label
| 1: With label
|
| Blank (0 fixed)
SENSOR2 [H]23℃ [A]22℃
| | Ambient air temperature sensor status (0 to 86℃, if not detectable –℃)
|
| Thermal head temperature sensor status (0 to 86℃)
[R]4.2V [T]2.5V
| | Transmission sensor status (0.0 to 5.0V)
|
| Reflective sensor status (0.0 to 5.0V)
PE LV. [R]1.8V [T]2.5V
| | Transmission sensor No paper level (0.0 to 5.0V)
|
| Reflection sensor, no paper level (0.0 to 5.0V)
M.THRE. [R] 1.8V
1.9V 2.0V 2.1V 2.2V
| Reflective sensor manual threshold level 1 to 5 (0.0 to 5.0V)
[T] 2.5V
2.4V 2.3V 2.2V.2.1V
| Transmission sensor manual threshold level 1 to 5 (0.0 to 5.0V)