178 GX9 ASD Installation and Operation Manual
Preset Speed 3 Start/Run Time
Program Frequency Preset Speed Time Settings
In conjunction with the setting of F587, this parameter is used to set the start-
time and run-time of Preset Speed 3 when used as part of a Pattern Run.
Settings:
Seconds From Start
Minutes From Start
Seconds From Reach
Minutes From Reach
Infinite (Until Stop Command)
Continue Until Next Step
Direct Access Number — F572
Parameter Type — Selection List
Factory Default Seconds From Start
Changeable During Run — No
Preset Speed 4 Start/Run Time
Program Frequency Preset Speed Time Settings
In conjunction with the setting of F588, this parameter is used to set the start-
time and run-time of Preset Speed 4 when used as part of a Pattern Run.
Settings:
Seconds From Start
Minutes From Start
Seconds From Reach
Minutes From Reach
Infinite (Until Stop Command)
Continue Until Next Step
Direct Access Number — F573
Parameter Type — Selection List
Factory Default Seconds From Start
Changeable During Run — No
Preset Speed 5 Start/Run Time
Program Frequency Preset Speed Time Settings
In conjunction with the setting of F589, this parameter is used to set the start-
time and run-time of Preset Speed 5 when used as part of a Pattern Run.
Settings:
Seconds From Start
Minutes From Start
Seconds From Reach
Minutes From Reach
Infinite (Until Stop Command)
Continue Until Next Step
Direct Access Number — F574
Parameter Type — Selection List
Factory Default Seconds From Start
Changeable During Run — No
Preset Speed 6 Start/Run Time
Program Frequency Preset Speed Time Settings
In conjunction with the setting of F590, this parameter is used to set the start-
time and run-time of Preset Speed 6 when used as part of a Pattern Run.
Settings:
Seconds From Start
Minutes From Start
Seconds From Reach
Minutes From Reach
Infinite (Until Stop Command)
Continue Until Next Step
Direct Access Number — F575
Parameter Type — Selection List
Factory Default Seconds From Start
Changeable During Run — No