F0 System Parameters
Func. Name Descriptions
Range of
Setting
Unit
Factory
Setting
Note
F0.00
Drive
Information
0: Software version
1: Drive model number
2: Drive rated current
3: Drive running hours
4: Drive supply power time
5: Software checksum code
─ ─ ─
F0.01
Parameter
Lock
0: Parameters are changeable
1: Parameters are locked
0, 1 ─ 0
F0.02 Reserved Reserved ─ ─ ─
*Note 9
F0.03 Reserved Reserved ─ ─ ─
*Note 9
F0.04 Reserved Reserved ─ ─ ─
*Note 9
100.0~120.0
*Note 3
110.0
*Note 3
190.0~240.0
*Note 4
220.0
*Note 4
F0.05
Power
Source
The value of setting according to
the actual power source
340.0~480.0
*Note 5
0.1V
380.0
*Note 5
*Note 9
F0.08
Fault
Record 1
─ ─ ─
*Note 9
F0.09
Reserved ─ ─ ─
*Note 9
F0.10
Reserved ─ ─ ─
*Note 9
F0.11
Reserved ─ ─ ─
*Note 9
F0.12
Reserved ─ ─ ─
*Note 9
F0.13
Reserved
0: Fault code
1: Output current at drive fault
2: DC bus voltage at drive fault
3: Output frequency at drive fault
─ ─ ─
*Note 9
F0.18
Function
0:brief 1:detail function 0,1
─ 0
F0.19 Reserved
Reserved
*Note 9
0: Disable
CLF: Clear fault records
dF60: Default the factory setting
of 60Hz
dF50: Default the factory setting
of 50Hz
SAv: Store setting
F0.20
Default
Setting
rES: Resume setting
─ ─ 0
The color as means functions can be set during the operation.
20