4–10
To take a measurement in segregation mode, select the mode as
described on page 2–16.
Press the 〈ENTER/START〉 key. The gauge displays:
Segregation Mode
Reading #: 1
Press <START>
<STORE>/<ESC> to End
Place the gauge on the first test site and press 〈ENTER/START〉.
The gauge takes a measurement, then displays the results:
Avg D: ##.#
Hi D: ##.#
Low D: ##.#
Den: ##.# <ENTER>
NOTE
If the Temperature option (see page 2–10) is installed, the
mat temperature is also shown in the upper right corner
of the display.
Press 〈ENTER/START〉 to continue. Repeat the previous steps to
take a measurement at up to 30 test locations. When all locations are
complete, press the 〈STORE〉 or 〈ESC〉 key to continue.
If the 〈ESC〉 key is pressed, the gauge displays:
End of Measurement
Do You Want To
Store ?
<YES> or <NO>
Press 〈NO〉 to return to the Ready screen without storing the results
or 〈YES〉 to continue as described below.