EasyManua.ls Logo

Troxler PaveTracker Plus - Page 57

Troxler PaveTracker Plus
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Model 2701-B 4–11
4. USING THE GAUGE
If the STORE key is pressed at the end of the measurements (or if
the operator presses ESC then YES), the gauge displays:
Do You Want To
Add Notes?
<YES> or <NO>
When storing test results, the gauge can also store project notes,
such as location information, with the measurement data. To include
project notes, press YES. The gauge displays:
Input Location
Press <ENTER>
Enter any desired information (up to eight characters) and press
ENTER/START. The gauge stores the last displayed results and
notes under the active project and returns to the Ready screen. For
more information on storing measured data, see the Storing Data
section on page 5–8.
NOTE
The gauge stores only the data shown in the last display.
It does not store the results of each individual reading.

Table of Contents

Related product manuals