9
Operation 3
Amendment 10
11 May 2015
Changing Operator Settings
With the Oven in ‘Stand-By’ Mode (i.e. Power to oven but both displays blank).
1. ENTER OPERATOR PARAMETER MODE.
Press and hold 'Steam' and ‘Timer-Start/Stop’ keys together.
‘Upper’ Dis
play will show ‘PAS’.
‘Lower’ Display will flash ‘000’.
2. SETTING PASSWORD (Operator Password - 123).
R
otate ‘Timer Control’ to set password.
(123 - Operator Password)
Pres
s ‘Light’ key to confirm password.
‘Upper Display’ will show one of the Parameter Codes, eg.
‘Lower Display’ will show the parameter value.
3. SETTING THE PARAMETERS.
R
otate ‘Timer’ knob to the parameter required.
Press ‘Light’ key to confirm parameter required. ‘Lower Display’ will flash.
While ‘Lower Display’ is flashing, rotate ‘Timer’ knob to select value required.
Press ‘Light’ key to confirm value. ‘Lower Display’ will stop flashing.
4. EXITING THE PARAMETER MODE.
Pres
s ‘On/Off’ key, to return to Stand-By Mode.
Operator Settings
Setting
Number
Description
Default
Setting
Oven Pre-Heat; - (Automatic Pre-Heat Temp on oven start-up).
150ºC
302ºF
Light Auto ‘Off’ Setting Time -
0 = ‘On/Off’.
1 = 1 minute auto ‘Off’.
2 = 2 minutes auto ‘Off’, etc.
0
Alarm Volume - Can be adjusted to suit operators preference.
5
Program Pre-Heating Condition - This setting allows for pre-heating ‘Ready’ temperature in
‘Program Mode’ Mode to be set higher than Program Set Temperature. Factory Default Setting
is ‘0’ (Equal to Program Setting).
0
Multi-Stage Enable (From Ser. No. 762120 only).- This setting enables multi-stage
programming. Factory Default Setting is ‘YES’, multi-stage programming is enabled.
Changing this setting to ‘no’ simplifies programming and program cooking.
YES
Setting
Range
60 - 260°C
140 - 500°F.
0 - 60 mins.
0 - 10.
0 - 30°C
0 - 54°F.
‘YES’ or ‘no’.