22
6 Controller Programming
Amendment 10
11 May 2015
6.1 Viewing / Changing Service Parameters
With the Oven in ‘Stand-By’ Mode (i.e. Power to oven but both displays blank).
1. ENTER SERVICE PARAMETER MODE.
Press and hold 'Steam' and ‘T
imer-Start/Stop’ keys together for 3 seconds.
‘Upper’ Display will show ‘PAS’.
The ‘Lower’ Display will flash.
2. SET PASSWORD (Service / Factory Password - 321).
Rotate ‘Timer Control’ to set password;
(
321 - Service Password).
Press ‘Light’ key to confirm password.
‘Upper’ Display will show one of the Parameter Codes.
‘Lower’ Display will show the parameter value.
3. SETTING THE PARAMETERS.
Rotate ‘T
imerKnob to the parameter required.
Pres
s ‘Light’ key to confirm parameter. ‘Lower Display’ will flash.
While ‘Lower Display’ is flashing, rotate ‘Timer’ Knob to select value required.
Press ‘Light’ key to confirm value. ‘Lower Display’ will stop flashing.
4. EXITING THE PARAMETER MODE.
Press ‘T
imer-Start/Stop’ to, to return to ‘Stand-By’ mode.