Specifications 1
Amendment 10
11 May 2015
Oven Gas Supply Requirements and Specifications
G32D5 (110 - 120V):
G32D4 (
240V) - UK Only:
Category: II
2H3P.
Flue Type: A
1.
G32D4 (
220 - 240V) - All Other Markets:
Natural Gas LP Gas
Input Rating 35 MJ/hr. 35 MJ/hr.
1.75 kPa. 2.75 kPa.
Operating Pressure 1.05 kPa. 2.75 kPa.
Gas Connection ½” NPT.
Electrical Power Ratings 1 Phase, 110-120V, 60HZ, 220W.
Oven Tray Details
Tray Capacity
5 x US Full Pan.
Tray Spacing
85mm / 3
1
/
3
”.
Water Connection
¾” BSP with ¾” GHT Adaptor supplied (80 psi / 550 kPa
maximum pressure).
Supply Pressure
Natural Gas Propane
Input Rating 10 kW 10 kW
Supply Pressure 20 mbar 30 - 37 mbar
Operating Pressure 10 mbar 25 mbar
Gas Connection ½” BSP Male.
Electrical Power Ratings 220-240V, 1P+N+E, 50/60HZ, 200W.
Oven Tray Details
Tray Capacity
4, 18” x 26” / 460 x 660 Full Size Sheet Pan Capacity.
4, 600 x 400 Tray Capacity.
Tray Spacing
110mm.
Water Connection ¾” BSP (80 psi / 550 kPa maximum pressure).
Natural Gas LP Gas (Propane)
Input Rating 35 MJ/hr. 35 MJ/hr.
Supply Pressure 1.13 - 3.4 kPa. 2.75 - 5.0 kPa.
Operating Pressure 0.75 kPa. 2.35 kPa.
Gas Connection ½” BSP Male.
Electrical Power Ratings 220-240V, 1P+N+E, 50/60HZ, 200W.
Oven Tray Details
Tray Capacity
4 x US Full Pan / EN 600 x 400.
Tray Spacing
110mm.
Water Connection ¾” BSP (80 psi / 550 kPa maximum pressure).