ENKOFORM VMK
4.4.1 Bring panels over. Tightness
The easiest way of using the PANEL CONNECTOR MK
is to tie it first to the already fixed and plumbed
PANEL. Place the PANEL CONNECTOR MK keeping its
centre to the joint and fix it by means of two
WEDGES MK.
The adjoining PANEL will be some millimetres away
from the plumbed one. It is better if the BOARDS do
not touch each other yet.
The PANEL CONNECTOR MK is placed on the PANEL that is already
fixed and plumbed.
2 WEDGES MK are introduced in the PANEL CONNECTOR MK and
the already plumbed PANEL.
In the left PANEL, insert the wedge in the 1
st
hole of
the WALER and in the 2
nd
(starting from the centre)
of the PANEL CONNECTOR.
The other 2 WEDGES MK are introduced in the holes of the other
PANEL.
The WEDGES MK are introduced more.
If there is a gap of some millimetres between the two
BOARDS, it will go diminishing every time one of the
WEDGES MK of each side is introduced more.
Depending on the gap between the BOARDS, it may
be necessary to change the WEDGE MK from the
hole.
The joint will be finished and fixed when the BOARDS
of both PANELS have no gap between them.
4 WEDGES MK are introduced in the holes.
By introducing one of the WEDGES MK even more, the PANELS
come together.