ENKOFORM VMK
Construcción
64
ENKOFORM VMK
5.2.4 COLUMNS
4.2.4.1 Up to 70x70 cm
Components pro waler row:
Dimensionsofthecolumn[cm]
20/20 30/30 40/40 50/50 60/60 70/70
ProfileMK120/0,875
4 4 4 4 4 4
SpacertubeMK120/52
2 2 2 2 2 2
WalerMK120/1,125
2 2 2 2 2 2
CornerconnectorMK
2 2 2 2 2 2
Wedge
8 8 8 8 8 8
BoltsM16x90+NutM16+Washer
12 12 12 12 12 12
WalerVM20Clamp2T
8 8 12 16 16 20
OutsidecornerheadMK
4 4 4 4 4 4
Platenut15
4 4 4 4 4 4
Tierod1m
2 2 2 2 2 2
From20x20cm to 52x52 cm
From50x50cm to 70x70cm