Page 3-3
Maintenance - 3.4 - Deutsch Connectors
SL20
M
ALE
C
ONNECTOR
(P
LUG
)
1. Disconnect the male connector (plug) from the female connector (receptacle).
2. Using the flat end of the Removal Tool (or flat blade screwdriver), pry the Locking Wedge
from the Male Connector. Care should be taken that the Silicon Gasket is not damaged dur-
ing this procedure.
3. Check all parts for damage. Replace all parts which are damaged or worn.
4. Replace or recrimp the wires and contacts. Refer to “Crimping” procedure.
F
EMALE
C
ONNECTOR
(R
ECEPTACLE
)
1. Disconnect the male connector (plug) from the female connector (receptacle).
2. Using the notched end of the Removal Tool (or a wire hook), pull the Locking Wedge from
the Female Connector.
3. Check all parts for damage. Replace all parts which are damaged or worn.
4. Replace or recrimp the wires and contacts. Refer to “Crimping” procedure.
R
ELEASING
L
OCKING
F
INGERS
Figure 3-3:
Locking Finger, Deutsch Connector
1. The Locking Fingers can be released
following the removal of the Locking
Wedge of either the male or female
connector.
2. Use the removal tool (or flat bladed
screwdriver) to push the Locking Fin-
gers aside. This will release the grip on
the contact.
3. Pull the wire and contact out of the con-
nector.
C
RIMPING
1. Strip 6 mm from the wire.
NOTE: Complete crimping
instructions are included in each
Field Kit.
2. Insert the contact into the crimping tool.
3. Insert the stripped wire into the contact. Copper strands should be visible in the bleed hole of
the contact and no copper strands should be loose (outside) of the contact barrel.
4. Completely close the handles of the crimping tool. Release the handles of the crimping tool
and remove the crimped contact.
5. Inspect the crimped contact to ensure that all strands are secure in the crimp barrel.
R
EMOVING
C
ONTACT FROM
H
EAVY
D
UTY
P
LUG
Figure 3-4:
Heavy Duty Deutsch Connector
1. Slip the removal tool along the wire to
be replaced.
2. Push the removal tool into the connec-
tor until the contact is released.
3. Pull the wire and contact out of the plug.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Upright SL20 Series and is the answer not in the manual?

Upright SL20 Series Specifications

General IconGeneral
BrandUpright
ModelSL20 Series
CategoryLifting Systems
LanguageEnglish

Related product manuals