User’s Guide ______________________________________________________________________
228 _________________________________________________________________ M211840EN-C
Table 52 Wind Parameters
Parameter Factory Range Info Command
Wind data
controls
Order
option
defined
1 = Dn Direction minimum
1 = Dm Direction average
1 = Dx Direction maximum
1 = Sn Speed minimum
1 = Sm Speed average
1 = Sx Speed maximum
0 = Reserved
0 = Reserved
[& = Delimiter]
0 = Dn Direction minimum
1 = Dm Direction average
0 = Dx Direction maximum
0 = Sn Speed minimum
1 = Sm Speed average
0 = Sx Speed maximum
0 = Reserved
0 = Reserved
Format:
1111110001001000
The first 8 are for combined
message and the last 8 for
composite message.
1 = Data is on
0 = Data is off
Note that you write the
parameter format
1111110001001000
but the unit answers
11111100&01001000.
WU,R
Wind update
interval
5 1 ... 3600 seconds WU,I
Wind
averaging
time
3 1 ... 3600 seconds WU,A
Wind speed
calculation
mode
1 1 = Max/min calculation
3 = Gust/lull calculation
WU,G
Wind speed
unit
M M = m/s, K = km/h,
S = mph, N = knots
WU,U
Wind
direction
offset
0 -180 ... 180 WU,D
NMEA
format
WT = XDR,
W = MWV
WU,N
Sampling
rate
4 1, 2, 4 Hz WU,F