Appendix H __________________________________________________ Configuration Parameters
VAISALA______________________________________________________________________ 229
Table 53 Precipitation Parameters
Parameter Factory Range Info Command
Precipitation
data
controls
1 = Rc Rain amount
1 = Rd Rain duration
1 = Ri Rain intensity
1 = Hc Hail amount
1 = Hd Hail duration
1 = Hi Hail intensity
1 = Rp Rain peak
1 = Rp Hail peak
[& = Delimiter]
1 = Rc Rain amount
1 = Rd Rain duration
1 = Ri Rain intensity
1 = Hc Hail amount
1 = Hd Hail duration
1 = Hi Hail intensity
1 = Rp Rain peak
1 = Rp Hail peak
Format:
1111110010000000
The first 8 are for combined
message and the last 8 for
composite message.
1 = Data is on
0 = Data is off
Note that you write the
parameter format
1111110010000000
but the unit answers
11111100&10000000.
RU,R
Precipitation
update
interval
60 1 ... 3600 seconds RU,I
Precipitation
unit
M M = metric (mm, s, mm/h)
I = imperial (in, s, in/h)
RU,U
Table 54 Auxiliary Sensor Parameters
Parameter Factory Range Info Command
Auxiliary
sensor
controls
Order
option
defined
1 = Tr pt1000 temperature
1 = Ra Aux. rain amount
1 = Sl Snow level
1 = Sr Solar radiation
1 = Rt pt1000 resistance
0 = Reserved
1 = Analog output mode*
0 = Reserved
[& = Delimiter]
1 = Tr pt1000 temperature
1 = Ra Aux. rain amount
1 = Sl Snow level
1 = Sr Solar radiation
1 = Rt pt1000 resistance
0 = Reserved
0 = Reserved
0 = Reserved
Format:
1111100011111000
The first 8 are for combined
message and the last 8 for
composite message.
1 = Data is on
0 = Data is off
Note that you write the
parameter format
1111100011111000
but the unit answers
11111000&11111000
*Note that Analog output
mode is never set when
external sensors are in use.
IU,R
Auxiliary
sensor
update
interval
60 0.5 ... 3600 seconds IU,I