Subject to modification! Updated 10/2017
BATTERY MODULE (VKB 56461701100)
Electrochemical cell
Nominal module capacity
Discharge depth
Useful module capacity
Connection
Cell monitoring
Dimensions in mm (W x H x D)
Weight
Packaging in mm (W x H x D)
Li-ion
3.3 kWh
90%
3.0 kWh
touch safe
integrated
445 x 110 x 339
25 kg
800 x 460 x 600
BATTERY MODULE (VKB 56462701100)
Electrochemical cell
Nominal module capacity
Discharge depth
Useful module capacity
Connection
Cell monitoring
Dimensions in mm (W x H x D)
Weight
Packaging in mm (W x H x D)
Li-ion
6.5 kWh
90%
5.9 kWh
touch safe
integrated
445 x 110 x 587
45 kg
800 x 460 x 600
Table 9: Technical parameters – battery modules
ENVIRONMENTAL RATING DATA
Environmental category
Classification of wet rooms
Degree of contamination
Ingress protection
Ambient temperature
Relative humidity
Max. altitude
Overvoltage category
Protection class
Air-conditioned indoors*
No wet rooms allowed
2
IP22
+5 °C to +30 °C
< 80%
2000 m ASL
III
1
*The energy storage system is completely enclosed by a building or housing. This protects the
energy storage system against sunlight, dust and other external influences. Additionally, the
building or housing is air-conditioned with regard to temperature, air humidity and air filtering.
Table 10: Technical parameters – environmental rating data