V-Touch AFAD
MAN-13
User’s Manual
25 Version 2.1
Figure 4-8 Gate configuration parameters
Selecting the Ignore Min Distance check box operates the gate without taking into account
the distance entered for the Minimum distance setting.
Minimum distance sets the smallest distance between two readings.
Retry sets the number of consecutive failures before registering an error
Starting delay sets the waiting time between the command and the actual gate motion start.
Timeout sets the duration of a complete gate motion.
Some Ver-Mac products offer a different parameters for the gate operation. Their motor is equipped
with a build-in potentiometer and limit switches.
Figure 4-9 Gate configuration parameters (continued)
Soft Start is used when starting the motor to ignore a certain number of cycles before the
motor reaches its maximum speed.
Since the displacement is evaluated every 100 ms, a value of 5 means that any error that
might occur in the first 500 ms will be ignored.