Configuration Parameters D-4
Appendix D: Using the Configuration File
Edge 5000 Installation / Configuration Guide
NETTIME date_format Sets the LCD display format for date.
Valid values are (MM: 2-digit month), (M: month), (DD: 2-digit
day), (D: day), (YYYY: 4-digit year), (YY: 2-digit year), (m: month
abbreviation), (d: day of week), '/', ',', '-'.
Default is DD m (21 Feb)”.
dst_auto_adjust Enables automatic daylight savings time (DST) adjustment by
the phone.
Valid values are 0 (disabled) or 1 (enabled).
Default is 1.
dst_start_month Sets month DST starts.
Valid values are 1 to 12, with 1 being January and 12 being
December.
Default is 3 in the United States.
dst_start_day Sets day of the month DST starts.
Valid values are the following:
•
1 to 31 (for day of the month)
• 0 (use value in the dst_start_day_of_week
parameter)
Default is 0.
dst_start_day_of_week Sets day of the week DST begins.
Valid values are 1 to 7 (1 is Sunday; 7 is Saturday).
Default is 1 in the United States.
dst_start_week_of_month Sets week of month DST begins.
Valid values are 1 to 6 and 7. One (1) is the first week; each
subsequent number is the subsequent week. Seven (7) is the
last week of the month regardless of which week the last week is.
Default is 2 for the United States.
dst_start_time Sets the hour of the day DST begins.
Valid values are 0 to 23.
The default is 2 for the United States.
dst_stop_month Sets month DST ends.
Valid values are 1 to 12 with 1 being January and 12 being
December.
The default is 11 for the United States.
Section Field Name Description