Loading...
Item Default Description
STS - Shared temperature
sense
Disabled The GX device will send the measured battery temperature to the
inverter/charger system as well as all connected solar chargers.
Temperature sensor Automatic Select the temperature sensor to use for shared temperature
sense measurement.
SCS - Shared current
sense
No Forwards the battery current, as measured by a battery monitor
connected to the GX device, to all connected solar chargers.
Controlling BMS Automatic Select the BMS that controls the battery.
SCS status - Describes if SCS is enabled, or why it is disabled
Display & language
Brightness Configure the brightness between 0 and 100%
Display off time - Set time-to-off between 10s / 30s - 1m / 10m /30m - or never
Show boat & motorhome
overview
Disabled Enable this to show the mobile overview page which is designed
for Marine and Remote Vehicle applications. This overview gives
direct access to the AC Current limit as well as the On/Off/
Charger-only settings and pump control. Also shows up to four
tank levels.
Language English Choose between English, Dutch, Chinese, German, Spanish,
French, Italian, Swedish, Turkish, Czech, Dansk, Polish, Russin
and Arabic.
Units °C The available options are Celsius and Fahrenheit. Please note
that this setting does not affect the temperature unit in the VRM
portal.
VRM online portal - Read full feature description [66]
Logging enabled Enabled Enable or disable logging
VRM Portal ID - Use this value when registering the GX device onto the VRM
Portal
Log interval 15 minutes Set to anything between 1 minute and 1 day. Choose longer times
on systems with an unreliable connection. Note that this setting
does not affect reporting problems and state changes (bulk →
absorption) to the VRM Portal. These events initiate an immediate
transmission of all parameters.
Use secure connection
(HTTPS)
Yes This encrypts the communication between the GX device and the
VRM server
Last contact - Time since the VRM server was last contacted
Connection error No error Displayed if there is an error in VRM communications. See here
for more details on troubleshooting VRM errors. [68]
VRM two-way
communication
Disabled Enable for VRM: Remote VEConfigure and VRM: Remote
firmware update
Reboot device when no
contact
Disabled The GX device will reset itself to attempt to correct a potential
networking issue if the internet connection is lost for the set delay
period
No contact reset delay
(hh:mm)
01:00 How long the unit must be offline before restarting itself
Storage location Internal storage Displays if an external storage device (eg USB drive or microSD
card) is mounted, or the internal storage is in use
Free disk space - Amount of bytes available on the storage device
microSD/USB - Select to safely eject an external microSD or USB storage (if one
is connected) before physically removing it. Failure to do so can
cause data loss.
Stored records - How many records are stored locally when no internet connection
is available. The GX device will store as many records as it can
locally, then upload them when internet is available again.
Oldest record age - If internet/VRM is not available, then this will display the oldest
record stored on the GX device.