This is a 24 hour zone operating all of the time even when the system is
disarmed. The line fail zone reports phone line failures from an external wired
receiver that is connected to a phone line.
Zxx: ZONE TYPE
22. PSU Fail
This is a 24 hour zone operating all of the time even when the system is
disarmed. The PSU fail zone reports power supply failures from an external
wired device.
Zxx: ZONE TYPE
23. Panic
This is a 24 hour zone operating all of the time even when the system is
disarmed. The panic zone reports panic events from any panic device to the
monitoring station or private telephone numbers. A panic event generates an
This zone type is active 24 hours, even when the system is disarmed. It is used
to report freezer trouble.
These Zone types are useful mainly to arm and disarm the system from inside the protected premises.
If you arm and disarm the system from outside (without tripping any sensor), such as using a keyfob, it
is preferred to use the other Zone Types.
3.4.3 Deleting a Device
Step 1
[1] Select the respective device
[2] Select exact device you wish
DELETE DEVICES
MOTION SENSORS
Z01:Motion Sens
ID No. 120-1254
Step 5
To delete the device: press the
Enter the Installer Menu, select the "02.ZONES/DEVICES" option (see section 3.2) and then select the
Select the respective group of the device you wish to delete. For example, "MOTION SENSORS".
Scroll the Device Group, identify (by zone and/or ID number) the exact device you wish to replace, for example:
"Z01: Motion Sensor > ID No. 120-1254" and press the button.
The display prompts you "<DEL> to Delete". To delete the device, press the (OFF) button.
D-306919 KP-250 PG2 Installer’s Guide 19