3.14.4 DD243 Setup
13:OPERATION MOD
⋅⋅⋅
03:DD243 SETUP
Enter the "03:DD243 SETUP" menu, and press to configure its settings.
Option and default Configuration Instructions
01:DISARM OPTION
entry/DD devs
Define when it is possible to disarm the system:
entry/DD devs - During entry delay, when the system is armed AWAY, by using
the keyfob or keyprox. Keypads cannot disarm at all.
entry/wl+away kp By the control panel when the system is armed AWAY. By
keyfob or keyprox during entry delay only.
anytime/all devAt any time and by all devices.
entry/all devs - During entry delay, when the system is armed AWAY, by all
devices. When not in entry delay by keyfob or keyprox only.
02:ENTRY ALARM
DD243
Define whether the system will report a confirmed alarm during an entry delay
(see CONFIRM ALARM below).
DD243 - An alarm initiated by another detector during the entry delay is not
regarded as a confirmed alarm.
normal mode - The control panel will report a confirmed alarm for the second
alarm that is triggered from a different zone within the confirmation time. There
are no alarm restrictions during entry delay or for the delay zone.
03:END EXIT MODE
fob/timer
Define how the exit delay is terminated or restarted according to the following
options:
fob/timer - By pressing the AUX button on the keyfob
11
, or when the exit delay
has expired, whichever first.
restart>reentry - Exit delay restarts when the door is reopened during exit delay.
The restart occurs once only. Restarting the exit delay is helpful if the user re-
enters immediately after going out to retrieve an item that was left behind.
door/fob/timer - When the door is closed, by pressing the AUX button on the
keyfob
1
, or when the exit delay has expired, whichever first.
door/fob only - When the door is closed, or by pressing the AUX button on the
keyfob
1
, whichever first.
04:FOB/KP PANIC
DD243
Define the devices that cannot trigger a panic alarm.
DD243KF-234 PG2 and KF-235 PG2.
all - All devices can trigger a panic alarm
05:CONFIRM ALARM
in 60 minutes
Define a specific time period that if 2 successive alarms occur, the second alarm will
be considered as a confirmed alarm, (see RPT CNFM ALRM below).
Options: disable and in 30/45/60/90 minutes
06:CONFIRM PANIC
A confirmed panic alarm is reported if one of the following occurs within the
11
Applies only when the keyfob is defined as "skip exit delay" (for further details, see the keyfob's User's Guide)
D-306919 KP-250 PG2 Installer’s Guide 77