3.5.5 Configuring Sirens Functionality
The following table provides you with a detailed description of each option and its configuration settings. To select an
option and change its configuration refer to section 3.5.1.
Option and default Configuration Instructions
43:PANEL SIREN
on
Determine whether the control panel’s built-in siren will sound alarms – “on” or remain
silent – “off”.
Options: on and off.
44:SIREN TIME
4 minutes
Define the period of time the sirens will sound upon alarm.
Previously known as "BELL
TIME"
Options: 1/90 seconds/3/4/8/10/15/20 minute(s).
Note: To comply with EN requirements, the "Siren Time" must not exceed
15 minutes.
45:STROBE TIME
20 minutes
Define the length of time the strobe light will flash upon alarm.
Options: 5/10/20/40/60 minutes.
46:SIREN ON LINE
disable on fail
Determine if the siren will be activated when the phone line fails and the system is
armed.
Options: disable on fail or enable on fail.
32 D-306919 KP-250 PG2 Installer’s Guide