3.14.3 BS8243 Setup
13:OPERATION MOD
⋅⋅⋅
02:BS8243 SETUP
Enter the "02:BS8243 SETUP " menu, and press to configure its settings.
Option and default Configuration Instructions
01:DISARM OPTION
entry/BS devs
Define when it is possible to disarm the system:
entry/BS devsBy keypad after the entry delay has expired and if an alarm occurred in
the system. By keyfob or keyprox at all times.
anytime/all devAt any time and by all devices.
entry/all devs - During entry delay, when the system is armed AWAY, by all devices.
When not in entry delay by keyfob or keyprox only.
entry/DD devs - During entry delay, when the system is armed AWAY, by using the
keyfob or keyprox. Keypads cannot disarm at all.
02:ENTRY ALARM
BS8243
Define whether the system will report a confirmed alarm during an entry delay (see
CONFIRM ALARM below).
BS8243 An alarm initiated by another detector during the entry delay is regarded as a
confirmed alarm. An additional 30 seconds delay is added to the entry delay for reporting
the event (does not affect the Abort Time, see section 3.5.4).
BS8243 no cnfrm - The panel will not send any confirmed alarm once a delay zone has
been activated, until the control panel is disarmed.
DD243 - An alarm initiated by another detector during the entry delay is not regarded as
a confirmed alarm.
normal mode - The control panel will report a confirmed alarm for the second alarm that
is triggered from a different zone within the confirmation time. There are no alarm
restrictions during entry delay or for the delay zone.
03:END EXIT MODE
door/fob only
Define how the exit delay is terminated or restarted according to the following
options:
door/fob only - When the door is closed, or by pressing the AUX button on the keyfob
1
,
whichever first.
fob/timer - By pressing the AUX button on the keyfob
10
, or when the exit delay has
expired, whichever first.
restart>reentry - Exit delay restarts when the door is reopened during exit delay. The
restart occurs once only. Restarting the exit delay is helpful if the user re-enters
immediately after going out to retrieve an item that was left behind.
door/fob/timer - When the door is closed, by pressing the AUX button on the keyfob
1
, or
when the exit delay has expired, whichever first.
04:FOB/KP PANIC
BS8243
Define the devices that cannot trigger a panic alarm.
BS8243KF-234 PG2 and KF-235 PG2.
all - All devices can trigger a panic alarm
10
Applies only when the keyfob is defined as "skip exit delay" (for further details, see the keyfob's User's Guide)
D-306919 KP-250 PG2 Installer’s Guide 75