05:CONFIRM ALARM
in 30 minutes
Define a specific time period that if 2 successive alarms occur, the second alarm will be
considered as a confirmed alarm, (see RPT CNFM ALRM below).
Options: in 30/45/60/90 minutes
06:CONFIRM PANIC
in 20 hours
A confirmed panic alarm is reported if one of the following occurs within the confirmation
time:
a) A second panic device is activated.
b) A second panic alarm on the same device is activated.
c) A tamper event is activated (not from the zone / device that initiated the panic alarm).
Options: in 4/8/12/20/24 hours and disable
07:RPT CNFM ALRM
enable+bypass
Define whether the system will report a confirmed alarm.
enable+bypass (default) - The system will report a confirmed alarm and will bypass all
alarmed open zones when the siren ends or when the confirmation timer expires.
disable - The system will not report a confirmed alarm.
enable - The system will report a confirmed alarm.
08:ENTRY DELAY 1
30 seconds
Two different entry delays allow the user to enter the protected site (while the system is
in the armed state) via 2 specific doors and routes without causing an alarm.
Following entry, the user must disarm the control panel before the entry delay expires.
Slow-rate warning beeps start sounding once the door is opened, until the last 10
seconds of the delay, during which the beeping rate increases. Locations No. 1 (entry
delay 1) and 2 (entry delay 2) allow you to program the length of these delays.
09:ENTRY DELAY 2
60 second
Options: 10/15/30/45/60 seconds; 3/4 minutes
10:ABORT TIME
in 30 seconds
The PowerMaster can be configured to provide a delay before reporting an alarm to the
monitoring station (not applicable to alarms from FIRE, 24H SILENT and EMERGENCY
zones). During this delay period, the siren sounds but the alarm is not reported. If the
user disarms the system within the delay time, the alarm is aborted. You can activate the
feature and select the "Abort Time" interval.
Options: in 00/15/30/45/60 seconds; in 2/3/4 minutes
11:CANCEL ALARM
in 5 minutes
The PowerMaster can be configured to provide a “Cancel Alarm” time window that starts
upon reporting an alarm to the Monitoring Station. If the user disarms the system within
that "cancel alarm" time, a “cancel alarm” message is sent to the Monitoring Station
indicating that the alarm was canceled by the user.
Options: in 1/5/15/60 minute/s; in 4 hours and not active
76 D-306919 KP-250 PG2 Installer’s Guide