Option and default Configuration Instructions
30 seconds
delay 1) and 2 (entry delay 2) allow you to program the length of these delays.
Options: 30/45/60 seconds; 3/4 minutes
10:ABORT TIME
in 15 seconds
The PowerMaster can be configured to provide a delay before reporting an alarm to
the monitoring station (not applicable to alarms from FIRE, 24H SILENT,
EMERGENCY, GAS FLOOD and TEMPERATURE zones). During this delay period,
the external siren will not sound and the alarm is not reported. If the user disarms the
system within the delay time, the alarm is aborted.
Options: in 15/30/45 seconds
11:CANCEL ALARM
in 5 minutes
Define the ”cancel alarm” period that starts upon reporting an alarm to the Monitoring
Station. If the user disarms the system within that time period, a “cancel alarm”
message is sent to the Monitoring Station.
Options: in 5/15/60 minutes; in 4 hours
12:CNCEL ANOUNCE
enable
Define whether a special beep will sound when an alarm cancel event is sent to the
monitoring station.
Options: enable and disable
13:ABORT ANOUNCE
enable
Define that when the user disarms the system within the allowed abort interval a special
beep will sound to indicate "no alarm transmission".
Options: enable and disable
3.14.6 OTHERS SETUP or EN50131 SETUP
13:OPERATION MOD
⋅⋅⋅
05:OTHERS SETUP or EN50131 SETUP
Enter the "05: OTHERS SETUP or EN50131 SETUP" menu, and press to configure its settings.
Option and default Configuration Instructions
01:DISARM OPTION
anytime
Certain regulations require that when the system is armed in AWAY mode, it may
not be disarmed from the outside of the house (such as by keyfobs) before entering
the protected premises and activating an "Entry Delay" zone. To answer this
requirement, the PowerMaster provides you with the following configurable options
to disarm the system:
A: At "any time" (default), the system can be disarmed at all times from all devices.
B: During entry delay, the system can be disarmed only using keyfob or prox
operated devices ("on entry wrless").
C: During entry delay by code, the system can be disarmed only using PowerMaster
panel keypad ("entry + away kp.").
D: During entry delay, the system can be disarmed using keyfobs or by code using
the PowerMaster panel keypad ("on entry all.").
03:END EXIT MODE
normal
The "Exit Delay" time can be further adjusted according to your preferred exit route.
The KP-250 PG2 provides you with the following "Exit Mode" options:
80 D-306919 KP-250 PG2 Installer’s Guide