Option and default Configuration Instructions
normal – The exit delay is exactly as defined.
restart>reentry - Exit delay restarts when the door is reopened during exit delay.
The restart occurs once only. Restarting the exit delay is helpful if the user re-enters
immediately after going out to retrieve an item that was left behind.
end by exit - The exit delay expires (ends) automatically when the exit door is
closed even if the defined exit delay time was not completed.
05:CONFIRM ALARM
in 60 minutes
Define a specific time period that if 2 successive alarms occur, the second alarm will be
considered as a confirmed alarm, (see RPT CNFM ALRM below).
Options: disable and in 30/45/60/90 minutes
07:RPT CNFM ALRM
disable
Define whether the system will report a confirmed alarm.
disable - The system will not report a confirmed alarm.
enable - The system will report a confirmed alarm.
08:ENTRY DELAY 1
30 seconds
Two different entry delays allow the user to enter the protected site (while the system is
in the armed state) using 2 specific doors and routes without causing an alarm.
Following entry, the user must disarm the control panel before the entry delay expires.
Slow-rate warning beeps start sounding once the door is opened, until the last 10
seconds of the delay, during which the beeping rate increases. Locations No. 1 (entry
delay 1) and 2 (entry delay 2) allow you to program the length of these delays.
09:ENTRY DELAY 2
15 seconds
Options: 00/15/30/45/60 seconds; 2/3/4 minutes
10:ABORT TIME
in 30 seconds
The PowerMaster can be configured to provide a delay before reporting an alarm to the
monitoring station (not applicable to alarms from FIRE, 24H SILENT, EMERGENCY,
GAS FLOOD and TEMPERATURE zones). During this delay period, the external siren
will not sound and the alarm is not reported. If the user disarms the system within the
delay time, the alarm is aborted.
Options: in 00/15/30/45/60 seconds; in 2/3/4 minutes
in 5 minutes
Define the “cancel alarm” period that starts upon reporting an alarm to the Monitoring
Station. If the user disarms the system within that time period, a “cancel alarm” message
is sent to the Monitoring Station.
Options: not active and in 1/5/15/60 minutes; in 4 hours