disable
Define whether the system will report events to the Monitoring Stations' SMS receivers via the
SMS Channel. For further information, see section 3.6.4 options 26 & 27.
Options: disable; enable.
Enter the name of the APN Access Point used for the internet settings for the GPRS (up to 16
Note: To enter the APN Access Point, use the “String Editor” in section 3.8.1.
Enter the Username of the APN used for GPRS communications (up to 16 digits string).
Note: To enter the Username, use the “String Editor” in section 3.8.1.
Enter the PIN code of the SIM card installed in the GSM module (up to 8 numerical digits).
Note: To enter the numerical PIN code, use the numerical keyboard.
Enter the Password of the APN used for GPRS communications (up to 16 digits string).
To enter the Password, use the “String Editor” in section 3.8.1.
The GSM roaming algorithm support cases where the panel is connected to the network but
the GPRS connection has timed-out. In such cases the panel attempts to connect to a different
network. Select one of the following options:
ROAMING
Modem roam en
Modem roam en
The internal cellular modems algorithm for roaming is enabled (roaming (en) = enable).
Roam disable en
Roaming is not allowed. Only the ‘Home’ network is enabled (accepted (en) = enable).
Manual roam en
The panels algorithm selects the best cellular operator (operator (en) = enable).
Lock network:
The operator that is defined in ‘Requested Operator’ option in the panel is selected ((en) =
enable).
Previously known as
"FORCE HOME
NTWK"
OPERATOR
This option specifies a preferred network for example, Vodafone UK. The device attempts to
register with this network when the signal strength is above the minimum CSQ value. When a
requested network is specified the device attempts to return to this network on every other
attempt.
Note: Contains an editable line to enter up to 6 MCC (Mobile Country Code) numbers +MNC
(Mobile Network Code) numbers.
Previously known as
"SESSION
TIMEOUT"
disable
Define whether the control panel will stay continuously connected "enable", via GPRS
communication, or disconnect "disable", after each report session.
Previously known as
"SESSION TIMEOUT"
Options: Enable or Disable.