Option and default Configuration Instructions
46:PSTN RETRIES
4 attempts
Define the number of times the system will retry to report to the Monitoring Station in case of
failure to report via the PSTN telephone line connection.
Options: 2 attempts; 4 attempts; 8 attempts; 12 attempts and 16 attempts.
47:GSM RETRIES
4 attempts
Define the number of times the system wil
l retry to report to the Monitoring Station in case of
failure to report via the cellular connection - GPRS (IP), GSM and SMS.
Options: 2 attempts; 4 attempts; 8 attempts; 12 attempts and 16 attempts.
48:BB IP RETRIES
4 attempts
Define the number
of times the system will retry to report to the Monitoring Station in case of
failure to report via the Broadband Module connection.
Options:
ommunication channel, the PowerMaster can be configured to send a test
event to the Monitoring Station via PSTN periodically. You can set the interval between the
consecutive test events or disable the automatic sending of this event entirely. If the inter
set for every one day or more then the exact hour of reporting can be selected with option 52.
Options: test OFF; every 1/2/5/7/14/30 day(s); and every 5 hours.
52:AUTO TST TIME
12:00
Enter the exact time (auto test time) during the day at which the Auto Test message (if enabled
in option 51) will be sent to the Monitoring Station.
Note: If the AM/PM format is used, you can set the "AM" and the "PM" digits using the numbers
on the keypad.
Determine whether a failure in any of the system communication channels i.e. PSTN,
GSM/GPRS, or Broadband will be reported or not and the time delay between detection of the
failure and reporting of the failure event to the Monitoring Station. A trouble event (i.e. "tel line
fail", "GSM line fail” or “broadband fail") will be respectively stored in the event log.
(Return)
Previously known as
"LINE FAIL REPORT"
Options "PSTN FAIL": immediate rprt; after 5/30/60/180 min and rprt disabled.
Options "GSM GPRS FAIL": after 2/5/15/30 min and do not report.
Options "
after 1/2/5/15/30 min, 1/3/6 hours
Define whether the system will report whenever 2 or more events (confirmed alarm) occur
during a specific period or enable the report and bypass the detector.
46 D-306919 KP-250 PG2 Installer’s Guide