Option Instructions
While in "TEST ALL DEVICES", press to initiate the test.
The devices are tested in the following order: wall-mounted devices, vanishing
magnetic contact devices, keyfobs and panic buttons.
At the end of the test process, the KP-250 PG2 will present the following: "SHOW
ALL DEVICES". Press to view devices' status.
Note: Refer to the "SHOW ALL DEVICES" section below for further information on
device status.
Pressing any key during the testing process will open the following options:
1. Press to jump to the next device group. For example, from wall-mounted
devices to keyfobs.
2. Press to continue the testing process
3. Press to exit the test process.
While in the vanishing test process, indicated by the corresponding display, for
example, "TEST VANISH XX", momentarily open the door or window.
While in the handheld devices test process, indicated by the corresponding display,
for example, "TEST KEYFOBS XX", press any key of the selected device to initiate
the test.
While in the panic button test process, indicated by the corresponding display, for
example, "TEST PANIC BT: XX", press a button on the pendant.
TEST ONE DEVICE
You can select a specific device group you wish to test, for example, Motion
Sensors.
Press to enter the "TEST ONE DEVICE" sub menu and use to scroll
through the device families. Press to enter the <device family> sub menu,
for example: "MOTION SENSORS".
The following screen will appear:
"Xxx:<device name>"
"<location>"
Where Xxx indicates the device number.
If there is no device, the following screen will appear: "NO EXISTING DEV.".
Press to test the selected device. The following screen will appear:
"TESTING Zxx NNN".
While in the handheld devices test process, indicated by the corresponding display,
for example, "TEST KEYFOBS 01", press any key of the selected handheld device
to initiate the test.
CONTACT SENSORS
MOTION SENSORS
GLASSBREAK SENS.