Common area zone types Definition
Gas; Temperature; 24-hour
silent; 24-hour audible
Non alarm Always ignored. There are no alarms for non-alarm zone types. Can be used for
example to activate PGMs without alarms in all modes.
Outdoor Acts as defined only after the last assigned partition is armed HOME or AWAY.
Arming key Arming all assigned partitions.
Tamper, Line Fail, PSU Fail,
Panic
Always armed.
Non alarm Always ignored. There are no alarms for non-alarm zone types. Can be used for
example to activate PGMs without alarms in all modes.
Outdoor Acts as defined only after the last assigned partition is armed HOME or AWAY.
Arming key Arming all assigned partitions.
Tamper, Line Fail, PSU Fail,
Panic
Always armed.
Note: A Soak Test of Common areas cannot be initiated when one of its partitions is armed. When Soak Test of a
Common area is active, an alarm event is ignored unless all the partitions that are assigned to the zone are armed.