72
LED Error Messages
ERROR CODE MESSAGES
POWER LED
LAMP LED
TEMP LED
FILTER LED
Lamp Ready
ON
Start
Flashing
Cooling
Flashing
Over Temperature
ON
Thermal Break Sensor error
4 blinks
Lamp Re-Strike 6 times Failed
5 blinks
Lamp Temperature shut down (Ballast
Temp)
5 blinks
1 blinks
Lamp Short circuit in output detected
(Ballast circuit short)
5 blinks
2 blinks
Lamp End of lamp life detected
5 blinks
3 blinks
Lamp did not ignite
5 blinks
4 blinks
Lamp extinguished during normal
operation
5 blinks
5 blinks
Lamp extinguished during run-up phase
5 blinks
6 blinks
Lamp voltage too low
5 blinks
7 blinks
Lamp Ballast Fail
5 blinks
8 blinks
Lamp Ballast COMM Fail
5 blinks
10 blinks
Lamp Ballast Over Temp
5 blinks
11 blinks
Lamp voltage too low
5 blinks
12 blinks
FAN1 error(Blower FAN1)
6 blinks
1 blinks
FAN2 error(Blower FAN2)
6 blinks
2 blinks
FAN3 error(Lamp FAN3)
6 blinks
3 blinks
FAN4 error(DMD FAN)
6 blinks
4 blinks
FAN5 error (Power FAN)
6 blinks
5 blinks
1W MCU detects scaler stops working
2 blinks
Case Open
7 blinks
DMD error
8 blinks
DDP442x not ready
8 blinks
1 blinks
Color wheel error
9 blinks
Air Filter replace warning
ON
ON
In the event of an error, please disconnect the AC power cord and wait for one (1) minute before restarting
the projector. If the Power or Lamp LEDs are still blinking or the Over Temp LED is lit, contact your service
center.