A122 Flow fault +
The ow rate is above the limit entered in the paint recipe (see Chapter 7.11).
− Replace gun nozzle (Airless and AirCoat).
− Check the lines for leakage.
− Set the opening of the gun needle correctly (air guns only).
− Decrease the pressure of the supply pumps.
A123 Flushing rst
The system has to be ushed.
The "Mixing alarm
flushing" or "Pot life alarm flushing" is activated and a mixing or pot
life alarm has occurred.
A124 No ow during lling
The lling procedure is interrupted for too long (longer than the "Alarm delay no ow
during lling" setting).
− Possibly, the lling procedure is waiting for the gun to be opened:
− With gun ush box: check whether the gun is inserted correctly.
− Without gun ush box: point spray gun into waste tank and open it.
− Check dump valve: clogging, function.
A125 No ow during ushing
The ushing procedure is interrupted for too long (longer than the "Alarm delay no ow
during ushing" setting).
− Possibly, the ushing procedure is waiting for the gun to be opened:
− With gun ush box: check whether the gun is inserted correctly.
− Without gun ush box: point spray gun into waste tank and open it.
− Check dump valve: clogging, function.
A126 Gun monitoring deactivated
Function is selected, which requires gun monitoring. However, the gun monitoring is
deactivated. Activate the gun monitoring or deactivate the relevant function.
Functions which require gun monitoring:
− Flow monitoring (settings password level 3).
− Spray gun closed
valves closed (settings password level 3).
− Dump valve as return line (settings password level 3).
A127 K factor is 0!
The new K factor "Kn" is 0 and can therefore not be saved.
A128/A129/A130/A131 Coriolis A/B/C/D
For Coriolis error, see operating manual of Coriolis ow meter.
A132/A133/A134/A135 Pot life gun 1/2/3/4
Pot life + post-alarm time have expired. Continue working immediately or ush.