5.10 FLOW MEASUREMENT
The ow of components A, B, C and D can be measured as follows:
− with ow meters
− Gear ow meters
− Coriolis ow meters (contact-free)
− with stroke sensors (contact-free, from software version 4.0x / 4.0x K)
Only one measuring method can be used within a component. It is however possible, for
example, to use stroke sensors for component A and ow meters for component B.
5.10.1 FLOW METERS
For every component, there is a ow meter installed upstream of the mixing block (gear or
Coriolis ow meter).
B_04356
A2
A1
B
A
B
A+B
Zener barriers
Touch screen /
controller
Ex zone
Non-Ex zone
Control cabinet
Flushing
Flow meter
Example: 2K system with 4 pumps in
potentially explosive zone
Flow meter
For operating ranges and technical data of the ow meters, see Chapters 5.5.3 and 5.5.4.