61
OPERATING MANUAL
VERSION 05/2017 ORDER NUMBER DOC 2357061
7.10 ENTER FLUSHING RECIPE
B_05202
Step
Flushing Qty
20.0
Menu
Menu
bar
Select existing ushing recipe.
(New ushing recipe: see Chapter 7.9.1)
Current ushing step for input on this page.
Dene total number of ushing steps for this recipe.
1–16
Select action for this ushing step.
Flushing valve to open, or
(=wait)
(=extend gun change)
(Chapter 7.13.2, level 3, page 21)
(last used A/B/C/D
product)
Enter ushing quantity or ushing time
for this ushing step.
0.0–9999.9
Enter short ushing steps rst (rough
ushing) to begin with, then long ushing
steps (approx. twice the hose content).
(No inuence on: " ")
Switch between ushing quantity
and ushing time.
cc or seconds
Go to next ushing step.
Repetitions can be
entered after the last
ushing step
(for examples, see
software documentation).
Flushing via dump valve:
on or o.
(Only with "Dump valve"
option)
Set ushing pressure.
(Only with "Automatic
product pressure
regulator" option)
With several guns, separate ushing steps
must be dened for each gun.
Only those guns which were in use are
ushed automatically.
Exception: if a system has already been
ushed, the guns indicated are ushed in
any case when ushing is repeated.
Opens the distributor valve for a
single gun (1, 2, 3 or 4) or for all
guns (1-x).
1 / 2 / 3 / 4 / 1-x
Example with splitter valve,
dump valve and product
pressure regulator