VERSION 05/2017 ORDER NUMBER DOC 2357061
Flow meter type
WAGNER Order No.
Note
Max.
pressure*
Flow rate
measuring range
Application
Low pressure /
High pressure /
XL
(without Pickup) bar l/min
Gear ow meter, 0.02-3 GL Ex 2343971 Standard slide bearing 400 0.02–3 Standard
/ /
Gear ow meter, 0.02-3 KL Ex 2343972 Standard ball bearing 400 0.02–3 Water-based lacquers
/ /
Gear ow meter, 0.005-2 GL Ex 2343973 Small quantity slide bearing 400 0.005–2 Small quantities
/ / --
Gear ow meter, 0.005-2 KL Ex 2334770 Small quantity ball bearing 400 0.005–2
better starting performance
with small quantities
/ / --
Gear ow meter, 0.005 – 0.5 KL Ex 2343974 Ball bearing 250 0.005–0.5
suitable for demineralised
water
/ / --
Gear ow meter, 0.005–1 GL Dual
Pickup Ex **
9955686
(with Pickup)
Slide bearing Dual Pickup
ow meter
530 0.005–1 for high-precision dosing
/ / --
Gear ow meter, 0.5-25 GL Ex 2311958 25 l/min slide bearing 530 0.5–25 extremely viscous media
-- / -- /
Gear ow meter, 0.1-7 GL Ex 2311948 7 l/min slide bearing 530 0.1–7 highly viscous media
/ /
Coriolis compact, 0.075–5 Ex 2359845 Coriolis DN 4 345 0.075–5 kg/min
high percentage of solid
objects
/ /
Coriolis compact, 0.15–10 Ex 2359846 Coriolis DN 6 345 0.15–10 kg/min
high percentage of solid
objects, highly viscous media
-- / -- /
Micro ow meter 0.005–0.25 Ex 2311618 Micro quantity 100 0.005–0.25
thin media without solid
objects
/ / --
Maximum viscosities for economical operation of the owmeters
Flow meter type
WAGNER Order No.
Max.
pressure *
Flow rate
measuring range
Viscosity limit values*** for
Product ltration
1 l/min 2 l/min 3 l/min
(without Pickup) bar l/min mPa s mPa s mPa s Mesh/inches
Gear ow meter, 0.02-3 GL Ex 2343971 400 0.02–3 5–1200 5–700 5–500 ≥ 100
Gear ow meter, 0.02-3 KL Ex 2343972 400 0.02–3 5–1200 5–700 5–500 ≥ 100
Gear ow meter, 0.005-2 GL Ex 2343973 400 0.005–2 5–500 5–200 -- ≥ 200
Gear ow meter, 0.005-2 KL Ex 2334770 400 0.005–2 5–500 5–200 -- ≥ 200
Gear ow meter, 0.005 – 0.5 KL Ex 2343974 250 0.005–0.5 1–100 (at 0.005–0.5 l/min) ≥ 200
Gear ow meter, 0.005–1 GL Dual Pickup Ex **
9955686
(with Pickup)
530 0.005–1 5–400 -- -- ≥ 200
Gear ow meter, 0.5-25 GL Ex 2311958 530 0.5–25 up to 8,000 up to 4,200 up to 3,200 ≥ 100
Gear ow meter, 0.1-7 GL Ex 2311948 530 0.1–7 5–4,000 5–2,100 5–1,600**** ≥ 100
Coriolis compact, 0.075–5 Ex 2359845 345 0.075–5 kg/min up to 600 up to 350 up to 250 --
Coriolis compact, 0.15–10 Ex 2359846 345 0.15–10 kg/min up to 1200 up to 700 up to 500 --
Micro ow meter, 0.005-0.25 Ex 2311618 100 0.005–0.25 0.5–6 (at 0.005–0.25 l/min) ≥ 300
* The maximum pressure of the ow meter must be greater than the maximum product pressure of the system (Fluid section type plate).
** Can not be combined with stroke measurement
*** All viscosity information are approximate values. The viscosities are recommended limit values for commercial operation.
**** at 7 l/min: 5–1000 mPas