28
OPERATING MANUAL
VERSION 05/2017 ORDER NUMBER DOC 2357061
5.5.1.1 LIMITATIONS FOR 2CIRCUIT SYSTEMS
Limitations for 2-circuit systems opposite the data in Chapter 5.5.1:
Standard
system
2-circuit system
2-circuit system
XL
per circuit per circuit
2K / 3K / 4K system 2K / 3K / 4K 2K / 3K
Maximum number of A/B/C/D paint and dosing valves 25/10/10/10 10/5/5/–
DN 10: 4/–/–/– *
DN 4: 10/5/5/– *
DN 2.6: –/5/5/– *
Maximum number of A/B/C/D ushing valves 10/5/5/5 5/2/2/–
DN 4: 1/1/1/– *
DN 2.6: –/1/1/– *
Maximum number of guns 4 2
Dump valve for waste separation
(option) --
External ushing
agent:
- Flushing over a period of time
(option) (option)
- Flushing with ow monitor
(option) (option)
- Flushing with ow meter
(option) --
Booster pump
(option) --
* More valves for XL version available on request.