86
OPERATING MANUAL
VERSION 05/2017 ORDER NUMBER DOC 2357061
9.1.4 CLEANING THE SYSTEM
The system should be cleaned for maintenance purposes. Ensure that no remaining
product dries on and sticks to the device.
A cleaned system allows an easy localization of any leakage and quick repair.
Procedure:
1.
Relieve the pressure according to Chapter 8.8.
2. Service guns and pumps according to their operating manuals.
3. Clean and check the suction systems and suction lter.
4. Product lter: check and clean lter insert and lter body.
5. Put the whole system back together.
6. Clean the outside of the system.
9.1.5 DECOMMISSIONING
1.
Clean the system according to Chapter 9.1.4.
2.
Fill the entire system with ushing agent. As laid down in Chapter 6.6.5, but with
ushing agent.
WARNING
Gas mixtures can explode if there is an incompletely filled pump!
Danger to life from ying parts.
Ensure that the device is always completely lled with ushing agent or working medium.
Do not spray the device empty after cleaning.
9.1.6 LONGTERM STORAGE
If storing the system for a prolonged period of time, thorough cleaning and corrosion
protection are necessary. For the last rinse, replace the water or solvent in the product
pumps with a suitable preservative. Fill separating agent cup with separating agent.
Store pump vertically.
Procedure:
1.
Clean the system according to Chapter 9.1.4.
2.
Fill the entire system with ushing agent. As laid down in Chapter 6.6.5, but with
ushing agent.
3.
Fill the entire system with preservative according to Chapter 6.6.5 and the lacquer
supplier's instructions.
4. If the discharge duct is to be removed, seal product outlet with plug.
5. If the suction system is to be removed, seal product inlet with plug.
6.
Storage according to Chapter 6.2.