93
OPERATING MANUAL
VERSION 05/2017 ORDER NUMBER DOC 2357061
10.1 ALARM MESSAGES
In the case of an alarm message, the system stops. The alarm horn sounds.
The red STOP push button lights up (control cabinet and remote control).
The fault is indicated on the screen.
Alarm No. Alarm message in the display Meaning
A100 B+ tol. alarm
Mixing ratio outside of tolerance range. B+/C+/D+: too much B/C/D.A101 C+ tol. alarm
A102 D+ tol. alarm
A103 B– tol. alarm
Mixing ratio outside of tolerance range. B–/C–/D–: too little B/C/D.A104 C– tol. alarm
A105 D– tol. alarm
A106 A+ ow rate
Maximum ow of components A/B/C/D exceeded.
A107 B+ ow rate
A108 C+ ow rate
A109 D+ ow rate
A110 A– ow rate
Falls below minimum ow of components A/B/C/D.
A111 B– ow rate
A112 C– ow rate
A113 D+ ow rate
A114 Air bubble A
Air bubble in the line (only with low-pressure).
A115 Air bubble B
A116 Air bubble C
A117 Air bubble D
A118 Flow meter A Flow meter A is blocked.
A119 Gun monitoring No gun signal, although product is owing.
A120 No enabling signal External release missing.
A121 Flow fault – The ow rate is below the limit entered in the paint recipe.
A122 Flow fault + The ow rate is above the limit entered in the paint recipe.
A123 Flushing rst The system has to be ushed.
A124 No ow during lling The lling procedure is interrupted for too long.
A125 No ow during ushing The ushing procedure is interrupted for too long.
A126 Gun monitoring disabled
Function is selected, which requires gun monitoring. However,
the gun monitoring is deactivated.
A127 K factor is 0! A K factor for the current paint recipe is zero. Calibrate.
Acknowledge alarm: By means of the STOP push button or on the screen with the [Reset]
button.
Fault rectication: see Chapter 10.1.1