B_01660
Mixing ratio volumetric A:B [A:1] (0= only A)
Flow-mixed product
A+B [L/min]
Working area
Standard
Flow meters: A: 0.5 – 25 l/min Viscosity:
B: 0.1 – 7 l/min Maximum viscosity depending on ow rate
5.5.4 APPLICATION LIMITS OF FLOW METERS
Viscosity
All viscosity information in this chapter are approximate values. The viscosities are recommended
limit values for commercial operation.
Particle size
Gear ow meters
Micro ow meter
0.005-0.25 Ex
Measuring range
from 0.02 l/min
Measuring range
from 0.005 l/min
Maximum particle size
120 µm 60 µm 40 µm
0.12 mm 0.06 mm 0.04 mm
0.0047 inch 0.0024 inch 0.0016 inch
Product ltration required min. 100 mesh/inches min. 200 mesh/inches min. 300 mesh/inches