6.4.1 ELECTRICAL CONNECTIONS
An electric connection cable with plug is standardly provided.
When exchanging the connection cable, please observe the following:
Carry out the electrical connections and the grounding inside the control unit using
a 3-wire cable of 1.5 mm; in accordance with the enclosed circuit diagram.
6.4.2 PNEUMATIC CONNECTIONS
Check whether the line pressure is sucient. It has to be between 0.7 and 0.8 MPa;
7to 8 bar; 101-116 psi.
WARNING
Overpressure!
Risk of injury from bursting components.
The operating pressure must not exceed the value shown on the type plate.
Check whether ecient lter systems and condensate precipitators are available in
the air line.
The compressed air must be free of oil and water. For compressed air quality, see
Chapter 5.5.1.
Every day, discharge all contamination and the condensate (if any) which has
accumulated in the equipment air lter.
WARNING
Brittle lter pressure regulator!
The tank on the lter pressure regulator becomes brittle through contact with solvents
and can burst. Flying parts can cause injury.
Do not clean the tank on the lter pressure regulator with solvents.
6.4.3 PRODUCT CONNECTIONS
Carry out the following connections:
Product hose from the mixing tube or splitter valve to the gun.
−
Electrostatic guns must be used without electrostatics during commissioning.
First commission the electrostatic system after all steps are carried out up to
Chapter 6.6.6.
The product hoses from the feeding pumps to the system's product inlets may not
be connected until the preliminary ushing of the hoses (see Chapter 6.6.1) has been
done (contamination of the unit)!
Circular pipeline
If the unit is connected to a circular pipeline, suitable shut-o devices must be installed
− to prevent the products from mixing in case of leakage in the 2K system.
− These shut-o devices must always be closed at the end of work.