14
OPERATING MANUAL
VERSION 05/2017 ORDER NUMBER DOC 2357061
3.2.2.1 IDENTIFICATION X
Ignition temperature
Ensure that the ignition temperature of the coating product is above the maximum
surface temperature of the work piece.
Ambient temperature
Permissible ambient temperature: +5 °C to +40 °C; +41 °F to +104 °F.
Medium supporting atomizing
To atomize the product, use only weakly oxidizing gases, e.g., air.
Surface spraying, electrostatics
Do not spray device parts using electrostatic equipment.
Cleaning
If there are deposits on the surfaces, the device may form electrostatic charges. Flames or
sparks can form during discharge.
Remove deposits from the surfaces to maintain conductivity.
Use only a damp cloth to clean the device.
3.2.3 USE IN AREAS SUBJECT TO EXPLOSION HAZARDS
Safe handling of WAGNER spray devices
Mechanical sparks can form if the device comes into contact with metal.
In an explosive atmosphere:
Do not knock or push the device or components against steel or rusty iron.
Do not drop the device or components.
Use only tools that are made of a permitted material.
National regulations
Ensure that the national explosion prevention rules and regulations are observed
when setting up the device.