EasyManua.ls Logo

WAGNER 2K COMFORT - Stroke Measuring

WAGNER 2K COMFORT
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39
OPERATING MANUAL
VERSION 05/2017 ORDER NUMBER DOC 2357061
5.10.2 STROKE MEASURING
For piston pumps, the ow can be measured contact-free with stroke sensors (from
software version 4.0x / 4.0x K). For this, each pump must be equipped with a stroke sensor.
There are three types of stroke sensors:
Stroke sensor type Field of application Working method
Stroke sensor short e.g., IceBreaker pumps up to 70 cm/DH
Detects the exact position of the piston.
Stroke sensor long e.g., IceBreaker pumps up to 100 cm/DH
Pressure sensor Flushing pump
Detects the piston's upper and lower
reversal points.
1
2
3
4
1
2
3
1/
1
2
3
2/
A2
A1
B
A
B
A+B
1/3
1/1
1/2
2/1
B_04357
Touch screen /
controller
Ex zone
Non-Ex zone
Control cabinet
Stroke sensor
Pressure sensor
Piston pump
Stroke sensor
Example: 2K system with 4 pumps in
potentially explosive zone
Flushing
A/D Converter (ADC)
The analog stroke sensor signals are evaluated in an A/D converter (ADC) and converted
into digital signals. Up to four A/D converters, with three inputs each, can be used. The ADC
automatically recognizes, whether a stroke sensor or a pressure sensor is connected to its
inputs (1, 2, 3).
Multiplexer (MPX)
In the control cabinet, a multiplexer processes the A/D converter's digital signals and
transmits the signals, of the currently active pumps, to the controller.

Table of Contents