94
OPERATING MANUAL
VERSION 05/2017 ORDER NUMBER DOC 2357061
Alarm No. Alarm message in the display Meaning
A128 Coriolis A
For Coriolis error, see operating manual of Coriolis ow meter.
A129 Coriolis B
A130 Coriolis C
A131 Coriolis D
A132 Pot life gun 1
Pot life + post-alarm time of guns 1/2/3/4 have expired.
A133 Pot life gun 2
A134 Pot life gun 3
A135 Pot life gun 4
A136 Pot life gun hose 1
Pot life + post-alarm time of gun hoses 1/2/3/4 have expired.
A137 Pot life gun hose 2
A138 Pot life gun hose 3
A139 Pot life gun hose 4
A140 Pot life to spl. valve The pot life + post-alarm time from mixer to splitter valve have expired.
A141 Pot life dump hose 1
Pot life + post-alarm time of dump hoses 1/2/3/4 have expired.
A142 Pot life dump hose 2
A143 Pot life dump hose 3
A144 Pot life dump hose 4
A145 Tank A is empty
Tank for component A/B/C/D is empty.
A146 Tank B is empty
A147 Tank C is empty
A148 Tank D is empty
A149 Tank ushing agent is empty Flushing agent tank is empty.
A150 Flow is too low
The setpoint ow is not reached with the ow regulation.
A151 Flow is too high
Acknowledge alarm: By means of the STOP push button or on the screen with the [Reset]
button.
Fault rectication: see Chapter 10.1.1